Assessment of smoking status in patients undergoing foot and ankle surgery

A. Swann, A. Goldberg, N. Cullen, D. Singh

1Royal National Orthopaedic Hospital, Foot and Ankle Unit, Stanmore, United Kingdom 

Introduction: Wound healing and poor bone healing are complications seen in patients who smoke and some surgeons prefer not to operate on smokers. However, self reporting of smoking by patients may be biased. This study compares self-reporting of smoking habits and cotinine levels in the urine of our patients.

Method: 77 patients admitted for an osteotomy or arthrodesis procedure between September 2013 and May 2014 agreed to participate in this study. A questionnaire was completed and a urine sample was obtained and tested for cotinine, a metabolite of nicotine, by 2 techniques: a dipstick, the COT One Step Cotinine Test, yielding a positive result when the cotinine in the urine exceeds 200 ng/mL and the Concateno laboratory assay test, providing a mean value to give a qualitative reading whereby the cut off for non-smokers is 500ng/ml.

Results: Questionnaire results showed that 12 participants were active smokers, 35 classed themselves as ex-smokers and 30 were non-smokers. A dipstick result was negative in all the non-smokers, in 31/35 (89%) of the ex-smokers and in 4/12 (25%) of the current smokers. The dipstick test was positive in 4 self-reporting ex-smokers and only 8 of the 12 current smokers. The laboratory assay gave readings from 21 to 45,657 with higher readings being from heavier smokers. It correctly gave a value < 500 for all self-reporting non-smokers but 3 of the 35 self-reporting ex-smokers had a value between 500-5000ng/ml.

Conclusion: Whilst the majority of our patients had matching self-reporting smoking status and urine cotinine levels, 10% of self-reported ex-smokers had a high level of urine cotinine due to the test limitations or reporting bias by our patients. The £1.50 COT dipstick test is a cheap and easy way to correctly confirm a non-smoker compared to the Concateno laboratory assay which costs £7 excluding portering costs.

Previous Article Assessing the risk factors in the management of diabetic ankle fractures: can rigid-long segment fixation (RISF) improve outcomes
Next Article Association between patient factors and outcome of synthetic cartilage hemiarthroplasty (Cartiva) versus first metatarsophalangeal joint arthrodesis in advanced hallux rigidus
Print


Click thumbnail below to view poster / thumbnail:

Archive of Abstracts

2024   -   Prize Winners  |  All Abstracts
2023   -   Prize Winners  |  All Abstracts
2022   -   Prize Winners  |  All Abstracts
2021   -   Prize Winners  
2019   -   Podium  |  Poster
2018   -   Podium  |  Poster
2017   -   Podium  |  Poster
2016   -   Podium  |  Poster
2015   -   Podium  |  Poster
2014   -   Podium  |  Poster
2013   -   Podium  |  Poster
2011   -   All Abstracts
2009   -   All Abstracts
2008   -   All Abstracts
2007   -   All Abstracts
2006   -   All Abstracts
2005   -   All Abstracts
2004   -   All Abstracts
2002   -   All Abstracts
2001   -   All Abstracts
2000   -   All Abstracts
1999   -   All Abstracts
1998   -   All Abstracts
1997   -   All Abstracts
1996   -   All Abstracts
1995   -   All Abstracts
1994   -   All Abstracts
1993   -   All Abstracts
1991   -   All Abstracts
1990   -   All Abstracts
1989   -   All Abstracts
1987   -   All Abstracts
1985   -   All Abstracts
1983   -   All Abstracts